Building a retaining wall in Spanish Fork is not only a landscaping decision. Taller walls, and some shorter walls that hold extra load, fall under the city’s adopted building code. This page summarizes the official rules we can cite, tells you where to apply, and flags the questions only the Building Department can answer for your lot.
We connect Spanish Fork homeowners with licensed local retaining wall contractors. We are not the city, and we are not the builder. A licensed contractor should confirm permit and engineering needs before you sign a contract. Call (385) 464-2708 or request a free quote. Quotes are referred to a licensed local contractor.
Codes change. Treat this as a guide to what to ask, then confirm with the Spanish Fork Building Department at 801-804-4540 (call or text) before you dig.
The 4-foot rule and how height is measured
Spanish Fork’s Design Criteria list the 2021 International Residential Code (IRC) and the 2024 International Building Code with Utah amendments as codes in effect.
Under 2021 IRC section R105.2, a building permit is not required for:
Retaining walls that are not over 4 feet (1219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge.
Two details in that sentence get missed:
- Height is measured from the bottom of the footing, not from the finished grade you see in the yard. A wall that looks 3 feet tall above ground can be over 4 feet once the buried base is counted.
- A surcharge removes the exemption, even if the wall is under 4 feet. A surcharge is extra load the wall has to resist besides the soil immediately behind it — typically a driveway, parking, a patio, a structure, or a steep slope above the wall.
If your wall is over that threshold, or it supports a surcharge, plan on a building permit and, in most cases, engineered plans.
When an engineer is required
Permit exemption and engineering are related but not identical. 2021 IRC section R404.4 generally requires that retaining walls be designed in accordance with accepted engineering practice when:
- The wall is not laterally supported at the top and retains more than 48 inches (4 feet) of unbalanced fill, or
- The wall is more than 24 inches (2 feet) high and resists lateral loads in addition to soil (again, a surcharge such as a driveway or slope).
The code also calls for a safety factor of 1.5 against sliding and overturning. This section does not apply to foundation walls that support a building.
In plain terms: a short garden wall with nothing but soil behind it may not need an engineer. A wall that holds a driveway, or a taller yard wall, often does. Ask the contractor and the city, and do not guess in order to save a design fee. A wall failure is much more expensive than a stamped plan.
Fences are a different rule than retaining walls
A wall that holds back soil is a retaining wall. A fence is a barrier for privacy or a property line. Spanish Fork treats them under different rules, and homeowners sometimes confuse the two.
Spanish Fork Municipal Code § 15.4.16.150 requires a building permit for all fences taller than 3 feet. The code states that no fee is charged for fence permits unless the permit is also required by the building code. In most non-industrial zones, the maximum fence height is 6 feet (fence pillars up to 6 1/2 feet). Industrial and public-facilities zones may allow up to 8 feet.
If you want a fence on top of a retaining wall, ask the city how they will measure the fence and whether both a fence permit and a retaining-wall building permit apply. Getting one wrong after the wall is built can mean a stop-work order or removal. The city’s Building Permits & Inspections page also lists fences among projects that commonly need a permit.
How to apply in Spanish Fork
Building permit applications are submitted online through CitizenServe, from the city’s Building Permits & Inspections page:
- Select Apply for a Permit.
- Log in or create an account.
- Select the appropriate permit type.
- Complete the application and upload the required documents (typically a site plan and, when required, engineered wall details and drainage).
If you are unsure which permit type to choose, call the Building Department at 801-804-4540. A licensed contractor you hire can often pull the permit as part of the job; that should be spelled out in the quote. This site does not pull permits for you.
Inspections
After a permit is issued, inspections are scheduled through CitizenServe at least 24 hours in advance. Work must be ready by 8 a.m. on the scheduled day. If it is not, a $93 re-inspection fee may apply. Early inspections can include setbacks and footings. Do not bury drain pipe, steel, or footings before they have been inspected if the permit requires those inspections. A final inspection is required when construction is complete.
Design criteria that affect wall design
From Spanish Fork’s official Design Criteria:
- Frost depth: 30 inches
- Average January temperature: 30°F
- Seismic Design Category D2, Site Class D (zip code 84660 reference point)
- Codes in effect include IRC 2021 and IBC 2024 with Utah amendments
These values are why a wall should not be stacked on loose dirt. The base has to deal with frost, engineered walls have to deal with seismic loads, and fine-grained Lake Bonneville soils common in southern Utah Valley can hold water. Drainage belongs in the plan. See wall types and the cost guide.
Call 811 before anyone digs
Blue Stakes of Utah 811 says to contact 811 at least three business days before digging, wait for utility marks, and dig carefully with hand tools within 24 inches of the marks. This applies to homeowners and contractors. Hitting a gas, power, water, or fiber line is dangerous and can leave you liable for the damage.
Also check for utility easements, irrigation lines, and any HOA design rules before you finalize a wall location.
Nearby cities and unincorporated county
If your property is not inside Spanish Fork city limits, do not use Spanish Fork’s portal. Permit rules for Springville, Payson, Salem, Mapleton, Santaquin, and unincorporated Utah County are on the service areas page. Several nearby cities also follow the 2021 IRC 4-foot rule, but contacts, fees, and local ordinances differ.
Official contacts
- Spanish Fork Building Department: 801-804-4540 (call or text), Building Division page
- City Hall: 40 S Main St., Spanish Fork, UT 84660; main city phone (801) 804-4500
- Apply and schedule inspections: CitizenServe, linked from Building Permits & Inspections
Get a free quote, then confirm the permit with the city
A licensed local contractor can tell you whether your wall is likely to need a permit and an engineer, include those costs in a written quote, and apply for the permit if you hire them. You still should feel free to call the city yourself.
Call (385) 464-2708 or request a free quote.
Sources cited on this page
- Spanish Fork City, Design Criteria
- Spanish Fork City, Building Permits & Inspections
- 2021 International Residential Code, sections R105.2 and R404.4
- Spanish Fork Municipal Code § 15.4.16.150, Fencing and Clear Vision Area
- Blue Stakes of Utah 811, Excavators’ Guide
- U.S. Geological Survey Professional Paper 257-B, Lake Bonneville: Geology of southern Utah Valley, Utah